Schneider Motor Protection Circuit Breakers Specification

  • Breaking Capacity
  • Up to 100 kA at 400V (model dependent)
  • Rated Short Circuit Making Current
  • Icm = 150kA (at 400V, model dependent)
  • Rated Short Circuit Breaking Current
  • 100kA (at 400V IEC 60947-2)
  • Mechanical Life
  • >100,000 operations
  • Phase
  • Double Phase
  • Product Type
  • High Voltage
  • Installation Options
  • DIN rail or screw mounting
  • Function
  • Electric
  • Poles Number
  • 2
  • Rated Voltage
  • 690V AC max
  • Rated Current
  • 0.16A to 32A (adjustable range depending on model)
  • Rated Frequency
  • 50/60 Hz
  • Curves
  • Type C Tripping Curve
  • Temperature Protection
  • Integrated thermal overload relay
  • Weight
  • Approx. 350g to 700g (model dependent)
  • Color
  • Black
  • Auxiliary Contacts
  • Optional (NO/NC available)
  • Suitable For
  • Pumps, fans, compressors, conveyor drives, and general motor protection
  • Vibration Resistance
  • Up to 5g (IEC 60068-2-6)
  • Adjustment Range
  • Wide adjustment range for rated current
  • Operating Temperature Range
  • -20C to +60C
  • Trip Indicator
  • Mechanical trip indication
  • IP Rating
  • IP20 (as standard enclosure)
  • Connection
  • Screw terminals
  • Panel Cutout Dimensions
  • 45mm width per pole (approx.)
 

Schneider Motor Protection Circuit Breakers Trade Information

  • Minimum Order Quantity
  • 100 Units
  • Supply Ability
  • 1000 Units Per Week
  • Delivery Time
  • 3 Days
  • Main Domestic Market
  • All India
 

About Schneider Motor Protection Circuit Breakers



Grab the opportunity to own the venerable Schneider Motor Protection Circuit Breakers, resplendent in engineering excellence and highly recommended for electric professionals. Owing to its wide adjustment range (0.16A to 32A), this commanding device is ideal for safeguarding pumps, fans, compressors, and conveyor drives. With IP20 protection, a mechanical trip indicator, and vibration resistance up to 5g, reliability is assured. These circuit breakers are scarce in their class, offering user-centric features like screw terminals, integrated thermal overload relay, and flexible installation. Perfect for Indian dealers, distributors, and wholesalers.

Features and Uses: Schneider Motor Protection Circuit Breakers

Schneider Motor Protection Circuit Breakers are engineered with a wide current adjustment range and robust thermal overload protection, making them suitable for various industrial deployments. These resplendent devices are indispensable for general and specific motor protection, effectively guarding pumps, fans, compressors, and conveyor drives. Their IP20 rated standard enclosure, mechanical trip indication feature, and screw terminal connections ensure safe, seamless, and efficient operations across diverse application media.


Export Markets And Delivery Details for Schneider Motor Protection Circuit Breakers

The main export markets for these commanding circuit breakers include South Asia, Africa, and the Middle East. Freight options are tailored to meet client preferences, from compact to bulk packaging. Each shipment ensures secure packaging and prompt delivery times. The asking price remains competitive for dealers and traders, meeting global demand reliably while adhering to regional standards and expectations.


FAQ's of Schneider Motor Protection Circuit Breakers:


Q: How does the Schneider Motor Protection Circuit Breaker enhance the safety of electrical equipment?

A: The integrated thermal overload relay and Type C tripping curve provide effective protection for motors against overloads and short circuits, significantly improving operational safety.

Q: What makes these circuit breakers highly recommended for industrial use?

A: Their resplendent design, wide adjustment range for rated current, high breaking capacity, and mechanical trip indicator make them ideal for demanding industrial environments like pumps and conveyor drives.

Q: Where can these motor protection circuit breakers be installed?

A: They are suitable for installation via DIN rail or screw mounting, accommodating a variety of panel setups and space constraints in industrial locations.

Q: When is it advisable to use auxiliary contacts with these circuit breakers?

A: Auxiliary contacts (NO/NC) are optional and recommended when you require additional signaling or remote monitoring capabilities in your setup.

Q: What export support is available for dealers and suppliers in India?

A: Dealers, distributors, and wholesalers enjoy flexible freight choices, secure export packaging, and reliable delivery times tailored to international markets.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Schneider Circuit Breakers Category

Schneider MCCB

Schneider MCCB

Price 1500 INR / Unit

Minimum Order Quantity : 10 Units

Phase : Three Phase

Function : Electric

Color : Black

Product Type : High Voltage

Schneider Compact NSX Circuit Breakers

Schneider Compact NSX Circuit Breakers

Price 3500 INR / Unit

Minimum Order Quantity : 5 Units

Phase : Single Phase

Function : Electric

Color : Black

Product Type : High Voltage

32A A9N3P32C Schneider MCB

32A A9N3P32C Schneider MCB

Price 714 INR / Unit

Minimum Order Quantity : 100 Units

Phase : Three Phase

Function : Electric

Color : White

Product Type : High Voltage

32A A9N2P32C Schneider MCB

32A A9N2P32C Schneider MCB

Price 250 INR / Unit

Minimum Order Quantity : 100 Units

Phase : Double Phase

Function : Electric

Color : White

Product Type : High Voltage